November 16,2023
Enterprise Name
The sealant has very strong adhesion and performs well even on glass and aluminum. After curing, it remains flexible and shows no cracking. Perfect for our facade projects.
Nov 17, 2026
Why choose fireproof building silicone sealant for curtain walls? Curtain wall perimeter joints are movement joints, and an open or cracked joint lets flame, smoke, water, and air pass between floors. A fireproof building silicone sealant stays flexible as glass, aluminum, and concrete expand and contract, and it helps limit the spread of flame and smoke through the gap. It also resists sunlight and ozone and works from -50°C to +150°C. I wrote this guide for US engineers, contractors, and buyers who need to match a sealant to a tested joint system and check the paperwork before work begins.
A curtain wall hangs down beyond the floor slabs, allowing room between them. Between tales, fire may travel. Smoke travels quicker due to the chimney effect. The gap shifts. The breadth fluctuates daily due to wind, temperature, and people moving between floors. The movement fractures a tough filler. Broken seals stop smoke and fire. This is why builders want an outside fire-safe, flexible joint seal. I check this joint first on any front.
Fireproof construction silicone sealant is gun-applied elastomeric. It seals water, fire, smoke, heat, and flame fractures. Not everyone in the US uses "fireproof." Fire-rated, fire-resistant, and firestop are preferable. Every lubricant burns by itself. Joint width, sealant depth, backing material, and substrates impact fire resistance in the tested assembly. People still want "fireproof," so I use both. A fire-rated junction may require smoke control or weathersealing elements depending on the strategy.
There are many ways US programs experiment. ASTM E1966 and UL 2079 determine fire-resistant joint system performance while moving. ASTM E119 defines building construction fire risk. ASTM E2307 evaluates curtain wall-floor fire barrier systems outdoors. Section 715 of the International Building Code addresses gaps and fissures. This section discusses the curtain wall-floor junction. The manager usually wants to see a listed system that fits your goals. I advise buyers to start with a proven configuration and then choose a suitable finish.
Fire and smoke can't spread through cracks in doors, windows, and other building parts when you use our fireproof building silicone sealant. When it dries, it turns into a tough seal that can be bent but won't break when things get rough. When crews use this RTV silicone, they don't mix it with anything else because it only needs water in the air to harden. You should let us know which test papers are right for your joint design before you place your order if you need a certain fire rating for your project.
Curtain wall joints may be damaged by sun, rain, wind, and weather changes. Our silicone formula doesn't fracture or powder after long-term sun exposure. Ozone and UV are no problem. It remains flexible between -50°C and 150°C. That stops working when it gets heated. The joint can move 50% up and down, so it can withstand shifting slabs and building vibrations. Silicone outlasts polyurethane and acrylic sealants outdoors. Tall facades are expensive to access again, therefore this is crucial.
The one-part acidic-cure silicone releases acetic acid, which smells like vinegar, as it dries. Although it adheres to glass and many covered surfaces, it may corrode metals and cement. Try a tiny test to check how well your aluminium coatings attach to concrete, steel, masonry, backing materials, and primers before mass production. ASTM C920 classifies elastomeric joint sealants by kind, grade, and movement class. You need a project-specific test to determine how effectively a sealant clings to your materials. Please notify us immediately if a base seems sensitive.
Instead of what the site expects, the joint should match the described arrangement. Check the joint width, sealant depth, backing material, bond-breaker requirements, and motion range. Be mindful of sharp edges on slabs, spandrel panels, mullion-transom junctions, and concrete-metal joints. Around the borders, fireproof construction silicone sealant and mineral wool backing are commonly used together, thus the list is more significant than any individual product. Discuss the details with the architect, facing engineer, firestop contractor, installer, and sealant supplier before starting construction. That meeting stops many pitch adjustments.
First, check to see if the surfaces are safe, clean, and dry. Fireproof building silicone sealant requires this surface preparation before application. There shouldn't be any dust, oil, laitance, release agents, or loose particles on them. If the system calls for it, use primer and gun the sealant in a single continuous bead with no holes or gaps. Make sure the approved detail is in place.
Stick the bead to both sides of the joint all the way, but don't stick it to all three sides, because that makes it hard to move. Our paste doesn't sag by more than 0 mm, according to the GB 13477 test. The surface dries in 45 to 60 minutes at 25°C and 50% relative humidity, so plan your work around that time.
We can see that it cures 3 mm every 24 hours at 25°C and 50% relative humidity. This means that lower joints need more time to move. That number changes in real life depending on the joint depth, temperature, humidity, and air flow. You can use our 300 ml cartridges for touch-ups and smaller tasks. We have 600 ml sausages for large façade runs where packs are changed less often. You can pick from black, white, gray, or your own color. The food will last for a year, so when you get it, check the dates to see when it was made and use the older stock first.
Many fire-tested procedures for these three compounds paint differently. UV radiation and water also damage them. For open curtain wall seams, silicone is utilised since it doesn't break readily in harsh weather. It adheres on metal and glass well. Polyurethane may be used for building joints if the project specifications allow. For internal joints that don't move much, acrylic is best. Order the same colour as the exterior as paint won't cling on silicone. Jiaobao has unique colours including white, black, grey, and others because of this.
Determine exposure direction, movement class, code, fire resistance duration, and smoke control. Make sure the fireproof building silicone sealant and backing are the proper size and kind for the junction and will be exposed inside or out. Next, inspect the adhesive, spring back, UV protection, temperature range, water performance, cure speed, shelf life, and directions. Buyers should also consider 300 ml and 600 ml packets, minimum order quantities, wait periods, batch uniformity, export paperwork, samples, and professional assistance. These are laid out for all approvers. This also makes seller comparisons fair.
According to tests done at 25°C and 50% relative humidity, here are the main technical values for our product.
| Property | Value |
|---|---|
| Type | One-part RTV silicone, acidic cure |
| Form | Paste |
| Colors | White, black, grey, or custom |
| Volume | 300 ml, 600 ml |
| Packaging | Sausage or cartridge |
| Shelf life | 12 months |
| Density (GB 13477) | 1.40 ± 0.05 g/cm³ |
| Non-volatile components (GB 2793) | 99.5% |
| Flow/sagging (GB 13477) | 0 mm |
| Surface drying time | 45–60 minutes |
| Curing speed | 3 mm/24 h |
| Temperature range | -50°C to +150°C |
| Displacement capacity | ±20% to ±50% |
| Water resistance | Class 1 W rating |
There are numbers in this set that will help you match our product to your needs line by line. If the value you need isn't on the list, send us your need, and we'll look it over with you.
Most people get it wrong when they think fireproof building silicone sealant is just a product claim without checking out the whole tried joint system. Adhesion, movement, cure, and fire performance can all be harmed if the joint sizes are wrong, the sealant is too thick, the backing is wrong, the surface is dirty, or the primer isn't approved. Installers shouldn't think that a joint that can handle fire can also handle smoke, water, and air. Packing that is old or broken, low humidity, or moving too fast are also things that can go wrong. More information, accepted mock-ups, field checks, and batch records can help lower these risks.
Before you do the real installation, make a model using the real substrates, coatings, glass types, backing, joint sizes, and ways of applying them. While changes are still cheap, the team can look at how it looks, how well it sticks, how well it works with other things, and how skilled the user is. You should schedule both formal fire tests and field adhesion tests. Field adhesion tests can show problems with primers or surface preparation, but they are not the same thing. I believe you should first get some samples. Sample cartridges let you try the extrusion and sealing on your own site before you buy a lot of them.
As of 2013, Shandong Jiaobao New Material Co., Ltd. manufactured colour silicone covers for almost 13 years. Quality control is consistent, proving this. CE, ISO, and others have validated our products. Ask for the product data sheet, safety data sheet, fire-test report, classification, tested joint design, sealant depth, backing specification, and movement rating with any pricing. Tell us your project needs. We manufacture anything in one to two weeks and ship by land or sea. We can create items to your country's OEM/ODM specifications. If the quality degrades throughout shelf life, we'll refund or replace.
Curtain walls have to be able to move with the wind, heat, and slab drift while keeping fire and smoke out. The one-part acidic-cure recipe for this fireproof building silicone sealant can move by up to 50%. It can do this as long as it stays flexible, doesn't combine with UV light or ozone, and can work from -50°C to +150°C. But the thing doesn't tell you how well it works. UL 2079, ASTM E2307, or ASTM E1966 must have been used to test a joint system for US work.
Plus, they need the right joint sizes, backing, surface prep, and time to cure. Fireproof building silicone sealant depends heavily on these proper installation conditions. Checks for compatibility must be done with acidic-cure chemistry before it can be used on sensitive substrates. Some of the ways that the match is checked before it is installed are mock-ups, field adhesion tests, and full submittals. It's smart to pick a sealer that works with the allowed joint and comes with proof.
It doesn't matter where the joints are or how big they are. What matters is where the substrates are, how they move, the backing, and the system being tried.
Not at all. The sealant is just one part of a system that might also have mineral wool backing.
It takes 45 to 60 minutes for the surface to dry at 25°C and 50% relative humidity. It hardens at a rate of 3 mm per 24 hours.
Silicone doesn't take paint, so don't use white, black, gray, or your own color.
The fireproof building silicone sealant will stay good for a year, so when it arrives, check the dates of production.
Want to buy fireproof building silicone sealant for building projects like doors, windows, and curtain walls? Jiaobao has 300 ml cartridges and 600 ml sausages. They have a one- to two-week lead time, do OEM/ODM work, and will replace or refund broken items within the shelf life. You can learn more at shandongjiaobao.com or send an email to dorashen@cnjiaobao.com with your joint drawings, materials, and order amounts.
1. International Code Council, International Building Code, 2021
2. ASTM International, ASTM E1966 Standard Test Method for Fire-Resistive Joint Systems, 2015
3. ASTM International, ASTM E2307 Standard Test Method for Determining Fire Resistance of Perimeter Fire Barrier Systems Using Intermediate-Scale, Multistory Test Apparatus, 2020
4. ASTM International, ASTM C920 Standard Specification for Elastomeric Joint Sealants, 2018
5. ASTM International, ASTM E119 Standard Test Methods for Fire Tests of Building Construction and Materials, 2020
6. UL Standards, UL 2079 Tests for Fire Resistance of Building Joint Systems, 2015
November 16,2023
Enterprise Name
The sealant has very strong adhesion and performs well even on glass and aluminum. After curing, it remains flexible and shows no cracking. Perfect for our facade projects.
November 16,2023
Enterprise Name
Stable quality across batches. Our customers especially like the smooth application and consistent extrusion. It helps reduce installation time on site.